本视频中演示了采用Young-Laplace方程拟合时各家接触角仪公司软件的区别。从测试结果来看,接触角变化范围从103-105度之间,属于一个合理的变化范围。这种变化由各种因素造成,如水的挥发等。
另可参考如下资料,我们发现国外的部分生产厂的接触角仪软件使用Young-Laplace拟合时,90-140度时,测值偏大5度,而大于140度时,测值偏大约10度。
Wemeasuredcontactangleofsamesamplewith4differentsoftwarefromKruss,Dataphysics,BiolinandKINO.AndwemeasuredcontactangleofsamplebyBiolin'ssofware-OneAttensionV2.4atfirstbecauseonlythissoftwarecannotimportimagesintosoftwareandcalculatecontactangleforimportedimage.OthersofwaressuchasDSA1.92andDSA3.0fromKruss,andSCA202fromDataphysicsandCAST3.0fromKINOcanallimportimageintosoftwareandcancalculatecontactangleusingdifferentmethodsuchascirclefittingmethod,ellispefittingmethodandYoung-Laplaceequationfittingmethod.Atthisarticle,wejustshowyouthecalculatedresultbydifferentcompany'ssoftware.Comparisonofmeasuredresultmaybehassomeexisteddeviationduetoourmisoperation.Youcancontactustoobtaintherecordedvideoformeasuringprocessofcontactangle.Andfromthecomparisonofmeasuredcontactanglefromdifferentdropshapesoftware,maysafelydrawaconclusionthat:1,Whencontactanglebelow3°: anti-dazz领screenmustbeusedtogetsharpdropshapeandwhenusingYoung-Laplaceequationfittingmethod,onlysofwarefromBiolin(OneAttensionV2.4)isfailuretofittingthedropshapeandgetaacceptablecontactangle.2,Whenthereexistssomenoisepointsorpoorbackgroud,tangentmethodbasedonpartsofdropprofilewill failuretofittingthedropshapeandgetaacceptablecontactangle.3,Whencontactanglebetween90°-140°,calculatedcontactanglebasedonYoung-LaplaceequationfittingmethodfromdropshapeanalysissoftwarefromKruss,DataphysicsandBiolinwillbelargerthanothermehodsuchascirclefittingandellispefittingabout3-5° whencirclefittingorellispefittingcanfittingthedropshape.And alsothisvaluebasedonYoung-LaplaceequationfittingmethodislargerthanADSA-RealDropbasedmethodfromKINOabout3-5°.4,Whencontactanglelargerthan140°, calculatedcontactanglebasedonYoung-LaplaceequationfittingmethodfromdropshapeanalysissoftwarefromKruss,DataphysicsandBiolinwillbelargerthanothermehodsuchascirclefittingandellispefittingabout8-10° whencirclefittingorellispefittingcanfittingthedropshape.And alsothisvaluebasedonYoung-LaplaceequationfittingmethodislargerthanADSA-RealDropbasedmethodfromKINOabout8-10°.5,CalculatedontactanglesbydifferentmethodfromKINO'ssofwareCAST3.0are almostkeptsamewhenbothofthemfittingdropshapecorrectly. Pleasebenotedthat,1, Abasicprincipleiscontactangleiscalculatedfromtangentatcontactpointorcurveradiusatcontactpoint.Andwhenfittingdropprofilewithsomeequationofcurve,ifresultoffittingisgood,calculatedcontactanglewillbealmostsame.Inotherwords,Young-Laplaceequationcanbeusedtocalculatecontactanglewhendropshapecannotfittingwithcircleequationduetoeffectofgravity.Butifweusedotherequationofcurveandfittingitcorrectly,theresultwillbekeptalmostsame.2,Rednumbermeansitisfailuretofittingdropprofilewithcurrentmethod.And"—"meanscurrentmethodcannotcalculateanyresultautomatically.仪器网-专业分析仪器服务平台,实验室仪器设备交易网,仪器行业专业网络宣传媒体。
相关热词:
等离子清洗机,反应釜,旋转蒸发仪,高精度温湿度计,露点仪,高效液相色谱仪价格,霉菌试验箱,跌落试验台,离子色谱仪价格,噪声计,高压灭菌器,集菌仪,接地电阻测试仪型号,柱温箱,旋涡混合仪,电热套,场强仪万能材料试验机价格,洗瓶机,匀浆机,耐候试验箱,se54se,熔融指数仪,透射电子显微镜。