型号NPF-120-12NPF-120-15NPF-120-20 NPF-120-24 NPF-120-30NPF-120-36 NPF-120-42 NPF-120-48 NPF-120-54
输出直流电压 12V 15V 20V 24V 30V 36V 42V 48V 54V
恒电流范围 7.2-12V 9-15V 12-20V 14.4-24V 18~30V 21.6-36V 25.2-42V 28.8-48V 32.4~54V
额定电流 10A 8A 6A 4A 3.4A 2.9A 2. 2.3A
额定功率120W 120W 120W 120W 120W 122.4W 121.8W 120W 124.2W
纹波与噪声(Zda)备注2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 250mVp-p 250mVp-p 350mVp-p
电压精度《3 ±4.0% ±4.0% +4.0% ±4.0% ±3.0% +2.0% ±1.0% +1.0% ±1.0%
线性调整率 ±0.5% ±0.5% +0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
负载调整率±2.0% ±1.5% 土1.0%±0.5%±0.5%±0.5%±0.5% 土0.5% ±0.5%
启动,上升时间备注4 500ms,80m(95%负载)115VAC/230VAC 保持时间(Typ.) 16ms/230VAC16ms/115VAC(满载时)
输入电压范围90?305VAC或127-431VDC
频率范围 47~63Hz
功率因数(Typ.) PF>0.97/115VAC,PF>0.96/230VAC,PF>0.94/277VAC(满载时)(请参考"功率因素特性曲线")
总谐波失真 THD<20%(115VAC/230VAC输入,输出负载>60%;277VAC输入输出负载>75%,) 效率(Typ.) 89% 89%90% 90.5% 89.5%90% 90% 90% 90.5%
交流电流(Typ.) 1.3A/115VAC0.6/230VAC0.5/277VAC 浪涌电流(Typ.) 冷启动60A(在50%Ipeak下测试twidth=520M5)/230VAC 漏电流 <0.25mA/277VAC
保护过电流95-108%
保护模式:恒电流限制,负载异常条件移除后可自动恢复
短路打嗝模式,异常条件移除后可自动恢复
过电压 15-17V17.5-21V23-27V28-34V34-40V 41~46V 46?54V 54~60V59-66V
保护模式:关断输出电压,重启恢复
过温度关断输出电压,重启恢复
环境工作温度 -40?+70。。(请参考"减额曲线")
工作湿度 20~95%RH,无冷凝
储存温度、湿度 ■40-+80oC,10-95%RH
温度系数±0.03%rc(0?50°C)
耐振动 10-500他,5612分钟/周期,乂、Y、Z轴各72分钟
安规和电磁兼容安全规范 UL8750,CSAC22.2No.250.13-12,ENECEN61347-1,EN61347-2-13,EN62384independent,IP67认证通过
耐压l/P-0/P:3.75KVAC
绝缘阻抗l/P-0/P:100MOhms/500VDC/25°C/70%RH
电磁兼容发射符合EN55015,EN61000-3-2ClassC(-60%负载);EN61000-3-3 电磁兼容抗扰度 符合£邮1000-4-2,3,4,5,6,8,1^呢1547,八级轻工业标准(浪涌2心) 其它MTBF >295.1KhrsMIL-HDBK-217F(25°C)
尺寸 191*63*37.5mm(L*W*H)
包装 0.97Kg;15pcs/15.6Kg/0.78CUFT