Specifications
Parameters/Test conditions | Min | Typ. | Max | Unit | Note | ||
1 | Signal Operating Wavelength | 1000 | 1064 | 1100 | nm | ||
2 | Pump Operating Wavelength | 800 | 1000 | nm | |||
3 |
Pump Fiber | Core Diameter | 105 | µm | Refer to fiber codes
| ||
4 | Cladding Diameter | 125 | µm | ||||
5 | Numerical Aperture | 0.15 | - | ||||
6 | Signal Fiber | HI1060 or 6/125 DCF | Refer to fiber codes | ||||
Pump Efficiency (%) | Signal Insertion Loss (dB) | Power Handling (W, each port) | |||||
7 |
Output Fiber | 6/125 DCF | >90(Typ.93) | <0.7(Typ. 0.5) | 25 | ||
10/125 DCF | >90(Typ. 93) | <0.7(Typ. 0.5) | 25 | ||||
12/125 DCF | >90(Typ. 93) | <0.7(Typ. 0.5) | 25 | ||||
15/125 DCF | >90(Typ. 93) | <0.7(Typ. 0.5) | 25 | ||||
20/125 DCF | >90(Typ. 93) | <0.7(Typ. 0.5) | 25 | ||||
20/200 DCF | >95(Typ. 97) | <0.7(Typ. 0.5) | 50 | ||||
25/250 DCF | >95(Typ. 97) | <0.7(Typ. 0.5) | 50 | ||||
30/250 DCF | >95(Typ. 97) | <0.7(Typ. 0.5) | 50 | ||||
20/400 DCF | >95(Typ. 97) | <0.7(Typ. 0.5) | 50 | ||||
8 | ㎡ | 1.3 | - | ||||
9 | Optical Isolation | 20 | dB | ||||
10 | Fiber Length | 0.8 | m | Each port | |||
11 | Operating Environment Temperature | -5 | +70 | ℃ | |||
12 | Operating Humidity | 5 | 95 | %RH | Not recommend in high humidity for long time. | ||
13 | Storage Temperature | -40 | +85 | ℃ | |||
14 | Package | C1, C2, C4, C7 | - | Handling power is different with PKG |
四川超光通信有限公司
仪器网(yiqi.com)--仪器行业网络宣传传媒