概述:
高精度、易用的单功能热电偶温度校准器
对于想要高精度、易用、单功能热电偶温度校准器的温度校准专业人员来说,Fluke714B是理想的测试工具。
714B可以测量和模拟(17)不同类型的热电偶和毫伏
测量4至20 mA信号,同时提供温度信号
悬挂工具设计在每个单元中并随附
可配置0%和100%源设置,用于快速25%线性检查
基于0%和100%设置的线性渐变和25%阶跃自动渐变
双输入和背光显示,便于解读测量结果
通电时记住断电设置,便于重新启动测试
1年和2年规格和可追溯的校准认证
技术指标:
General Specifications | |
Maximum voltage applied between any terminal and earth ground or between any two terminals | 30 V |
Operating temperature | -10 °C to 50 °C |
Storage temperature | - 30 °C to 60 °C |
Operating altitude | 2,000 meters |
Storage altitude | 12,000 meters |
Relative humidity (% RH operating without condensation) | Non condensing 90 % (10 °C to 30 °C) 75 % (30 °C to 40 °C) 45 % (40 °C to 50 °C) (Without condensation) |
Vibration requirements | MIL-T-28800E, Class 2 |
Drop text requirements | 1 meter |
IP Rating | IEC 60529: IP52 |
Electromagnetic environment | IEC 61326-1, Portable |
Safety | IEC 61010-1, Max 30 V to earth, Pollution Degree 2 |
Power supply | 4 AA NEDA 1.5A IEC LR6 batteries |
Size (H x W x L) | 52.5 mm x 84 mm x 188.5 mm |
Weight | 515 g |
DC mA Measurement | ||
Resolution | Range | Accuracy (% of reading + counts) |
0-24 mA | 0.001 mA | 0.010 % + 2 μA |
Temperature coefficient | ± (0.002 % of reading + 0.002 % of range) /°C ( <18 °C or >28 °C) |
Millivolt Measurement and Source | ||
Resolution | Range | Accuracy (% of reading +counts) |
-10 mV to 75 mV | 0.01 mV | 0.015 % + 10 μA |
Temperature coefficient | ± (0.002 % of reading + 0.002 % of range) /°C ( <18 °C or >28 °C) |
Thermocouple Input and Output | |||||
TC Type | Range (°C) | Measure (°C) | Source (°C) | ||
1 year | 2 year | 1 year | 2 year | ||
E | -250 to 200 °C | 1.3 | 2.0 | 0.6 | 0.9 |
-200 to -100 °C | 0.5 | 0.8 | 0.3 | 0.4 | |
-100 to 600 °C | 0.3 | 0.4 | 0.3 | 0.4 | |
600 to 1000 °C | 0.4 | 0.6 | 0.2 | 0.3 | |
N | -200 to -100 °C | 1.0 | 1.5 | 0.6 | 0.9 |
-100 to 900 °C | 0.5 | 0.8 | 0.5 | 0.8 | |
900 to 1300 °C | 0.6 | 0.9 | 0.3 | 0.4 | |
J | -210 to -100 °C | 0.6 | 0.9 | 0.3 | 0.4 |
-100 to 800 °C | 0.3 | 0.4 | 0.2 | 0.3 | |
800 to 1200 °C | 0.5 | 0.8 | 0.3 | 0.3 | |
K | -200 to -100 °C | 0.7 | 1.0 | 0.4 | 0.6 |
-100 to 400 °C | 0.3 | 0.4 | 0.3 | 0.4 | |
400 to 1200 °C | 0.5 | 0.8 | 0.3 | 0.4 | |
1200 to 1372 °C | 0.7 | 1.0 | 0.3 | 0.4 | |
T | -250 to -200 °C | 1.7 | 2.5 | 0.9 | 1.4 |
-200 to 0 °C | 0.6 | 0.9 | 0.4 | 0.6 | |
0 to 400 °C | 0.3 | 0.4 | 0.3 | 0.4 | |
B | 600 to 800 °C | 1.3 | 2.0 | 1.0 | 1.5 |
800 to 1000 °C | 1.0 | 1.5 | 0.8 | 1.2 | |
1000 to 1820 °C | 0.9 | 1.3 | 0.8 | 1.2 | |
R | -20 to 0 °C | 2.3 | 2.8 | 1.2 | 1.8 |
0 to 100 °C | 1.5 | 2.2 | 1.1 | 1.7 | |
100 to 1767 °C | 1.0 | 1.5 | 0.9 | 1.4 | |
S | -20 to 0 °C | 2.3 | 2.8 | 1.2 | 1.8 |
0 to 200 °C | 1.5 | 2.1 | 1.1 | 1.7 | |
200 to 1400 °C | 0.9 | 1.4 | 0.9 | 1.4 | |
1400 to 1767 °C | 1.1 | 1.7 | 1.0 | 1.5 | |
C | 0 to 800 °C | 0.6 | 0.9 | 0.6 | 0.9 |
800 to 1200 °C | 0.8 | 1.2 | 0.7 | 1.0 | |
1200 to 1800 °C | 1.1 | 1.6 | 0.9 | 1.4 | |
1800 to 2316 °C | 2.0 | 3.0 | 1.3 | 2.0 | |
L | -200 to -100 °C | 0.6 | 0.9 | 0.3 | 0.4 |
-100 to 800 °C | 0.3 | 0.4 | 0.2 | 0.3 | |
800 to 900 °C | 0.5 | 0.8 | 0.2 | 0.3 | |
U | -200 to 0 °C | 0.6 | 0.9 | 0.4 | 0.6 |
0 to 600 °C | 0.3 | 0.4 | 0.3 | 0.4 | |
BP | 0 to 1000 °C | 1.0 | 1.5 | 0.4 | 0.6 |
1000 to 2000 °C | 1.6 | 2.4 | 0.6 | 0.9 | |
2000 to 2500 °C | 2.0 | 3.0 | 0.8 | 1.2 | |
XK | -200 to 300 °C | 0.2 | 0.3 | 0.2 | 0.5 |
300 to 800 °C | 0.4 | 0.6 | 0.3 | 0.6 | |
G | 100 to 300 °C | 1.6 | 2.4 | 1.2 | 1.8 |
300 to 1500 °C | 1.0 | 1.5 | 1.0 | 1.5 | |
1500 to 2320 °C | 2.0 | 3.0 | 1.6 | 2.4 | |
D | 0 to 300 °C | 1.6 | 2.4 | 1.2 | 1.8 |
300 to 1500 °C | 1.0 | 1.5 | 1.0 | 1.5 | |
1500 to 2315 °C | 2.0 | 3.0 | 1.6 | 2.4 | |
P | 0 to 1000 °C | 1.6 | 2.4 | 0.6 | 0.9 |
1000 to 1395 °C | 2.0 | 3.0 | 0.8 | 1.2 | |
M | -50 to 100 °C | 1.0 | 1.5 | 0.4 | 0.6 |
100 to 1000 °C | 1.6 | 2.4 | 0.6 | 0.9 | |
1000 to 1410 °C | 2.0 | 3.0 | 0.8 | 1.2 |