Anprolene AN74I STARTER KIT Standard sterilizer system, 2.0 cu ft 115 VAC, 60 Hz

Gently sterilize delicate items that heat and moisture can damage
  • Sterilize any instrument, component, or material
  • Sterilizer requires less than 17.5 grams of Ethylene Oxide per cycle
  • Sterilize and aerate in the same cabinet

规格与描述

  • 腔室容量 (ft³)2
  • 腔室容量 (升)56.6
  • 腔室高度 (in)13
  • 腔室深度 (in)20
  • 宽度 (in)14
  • 高度 (in)20 1/2
  • 宽度 (cm)35.6
  • 高度 (cm)52
  • 定时器Yes
  • 定时器范围14 to 24 hours
  • 腔室构造Stainless Steel
  • 显示LCD
  • 功率 (VAC)115
  • 功率 (Hz)60
  • 描述Standard sterilizer system, 2.0 cu ft 115 VAC, 60 Hz

包括

(1) Sterilizer Cabinet, (25) small 5-ml ampoules with (25) 7-liter liner bags, (20) large 20-ml ampoules with (20) 35-liter liner bags, (50) Humidichip® relative humidity stabilizer chips, Humiditube chip holder, (50) EtO dose chemical indicator strip

主要特点

  • Sterilize any instrument, component, or material
  • Sterilizer requires less than 17.5 grams of Ethylene Oxide per cycle
  • Sterilize and aerate in the same cabinet

关于该商品的更多信息

These gas sterilizer systems use 100% Ethylene Oxide (EtO) to safely sterilize delicate items that heat and moisture can damage. EtO sterilizers operate at room temperature and atmospheric pressure—safe for electronics, fiber optics, cameras, and plastic or rubber items such as tubing. Sterilizers feature a combination of ventilation and purge systems ensuring that EtO exposure levels are below OSHA prescribed limits. The advanced purge system allows for items to be aerated in the sterilization cabinet for two hours at the end of a cycle and will continue indefinitely until items are removed.

Sterilizers use unique plastic liner bags and individual gas ampoules. Two sizes of bag/ampoule combinations are available to match the size of the load—never use more gas than you need to. Since sterilizer systems use only small amounts of EtO gas, they meet all EPA requirements without the need for expensive abatement equipment. A dedicated exhaust line to the outside for the outlet hose is all that is required. Order outlet hose separately. Sterilizer systems include everything necessary for the sterilization process, including biological and chemical indicators for verifying the sterility and EtO exposure of items. Sterilizers are available in two sizes—choose the long model for handling larger items.

Warning: This product is not approved or intended for, and should not be used for medical, clinical, surgical or other patient oriented applications.