找仪器

美国AST激光微光斑聚焦光谱仪

北京精科华腾科技有限公司

企业性质一般经销商

入驻年限第6年

营业执照已审核
同类产品MSP500(1件)

Microspectrophotometer MSP500 Introduction

Microspectrophotometer (Micro-Photometer, Micro Spectrophotometer) is used to characterize optical properties of thin films, thick coatings over a micron region area. Microspectrophotometer is also called microreflectometer, micro-reflectometer, microspectrometer, microphotometer (Spectroscopic), microspectroscopic photometer etc. With unique design by Angstrom's professionals, user can enjoy digital imaging capability in Microspectrophotometers (MSP series) by live video, powerful digital editing, measurement tools for reflection, transmission, absorption spectra. Data acquisition only takes milliseconds. TFProbe software allows user to set up heating stage or coo领 stage for kinetic study in real time for optical property changes such as reflectance, transmittance, coating thickness, refractive index (optical constants) etc. Automatic mapping function is also available in various Microspectrophotometer models with motorized X-Y stage or Rho-Theta Stage, plus the  motorized focus function. Wavelength range usually is an important factor for user to consider. Angstrom's microspectrophotometer covers from deep-ultraviolet (DUV) to near-infrared (NIR) ranges. Which range 首ld be considered will depend on several factors such as what are thickness ranges for thin film or thick coating, what is typical wavelength range of interest for reflectance or transmittance and so on. MSP500 is most advanced model which covers from 250 to 1700nm large wavlength range. Selectable options, motorized mapping stage, fluorence application attachment, are available.

 

FEATURES:

·         Easy to operate with Window based software

·         Advanced optics and rugged design for highest uptime and the best system performance

·         Array based detector system to ensure fast measurement

·         Affordable, portable and small footprint table top design

·         Measure film thickness and Refractive Index up to 5 layers over micron size region

·         Allow to acquire reflection, transmission and absorption spectra in milliseconds

·         Capable to be used for real time spectra, thickness, refractive index monitoring

·         System comes with comprehensive optical constants database and library

·         Advanced Software allows user to use either NK table, dispersion or composite model (EMA) for each individual film

·         Integrated Vision, spectrum, simulation, film thickness measurement system

·         Apply to many different type of substrates with different thickness up to 200mm size

·         2D and 3D output graphics and user friendly data management interface

·         Advanced Imaging software for dimension measurement such as angle, distance, area, particle counting and more

·         Various options available to meet special applications

SYSTEM CONFIGURATION:

·         Model: MSP500RTMF

·         Dual Detector System: CCD Array with 2048 pixels for UV-Vis and InGaAs Arrary for NIR

·         Light Source: High Power DUV and Visible

·         Stage: Black Anodized Aluminum Alloy with motorized travel distance 100mm by 75mm

·         Focus: Motorized Auto focus with Joystick control.

·         Long Working Distance Objectives: 10x, 15x, 50x (one DUV objective included)

·         Communication: USB

·         Software: TFProbe 2.4/2.5 with Fully automatic Mapping Capability and 2D/3D graphics outputs

·         Measurement Type: Reflection/Transmission spectra, Film thickness/refractive index, fluorescence and feature dimensions

·         Computer: Intel Core 2 Duo Processor with 200GB Hard drive and DVD+RW Burner plus 19” LCD Monitor

·         Power: 110– 240 VAC /50-60Hz, 3 A

·         Dimension: 16’x16’x18’ (Table top setup)

·         Weight: 120 lbs total

·         Warranty: One year labor and parts

SPECIFICATIONS:

·         Wavelength range: 250 to 1700 nm

·         Wavelength Resolution: 1nm for UV-Vis and 5 nm for NIR

·         Spot Size: 100µm (4x), 40µm (10x), 30µm (15x), 8µm (50x)

·         Substrate Size: up to 20mm thick

·         Measurable thickness range*: 2 nm to 50 µm

·         Measurement Time: 2 ms minimum

·         Accuracy*: better than 0.5% (comparing with ellipsometry results for Thermal Oxide sample by using the same optical constants)

·         Repeatability*: < 2Å (1 sigma from 50 thickness readings for 1500 Å Thermal SiO2 on Si Wafer)

OPTIONS:

·         Wavelength extension to Further DUV or longer NIR range (~2500nm)

·         Higher power optics for smaller spot size

·         Customized configuration for special applications

·         Heating and Coo领 Stage for dynamic study

·         Optional stage size holding samples up to 300mm

·         Higher wavelength range resolution down to 0.1nm

·         Various filters for special applications

·         Add-on accessories for fluorescence measurement

·         Add-on accessories for Raman applications

·         Add-on accessories for polarizing applications

·         Automatic Mapping Stage up to 300mm wafer

APPLICATIONS:

·         Semiconductor fabrication (PR, Oxide, Nitride..)

·         Liquid crystal display (ITO, PR, Cell gap…..)

·         Forensics, Biological films and materials

·         Inks, Mineralogy, Pigments, Toners

·         Pharmaceuticals, Medial Devices

·         Optical coatings, TiO2, SiO2, Ta2O5…..

·         Semiconductor compounds

·         Functional films in MEMS/MOEMS

·         Amorphous, nano and crystalline Si

APPLICATION EXAMPLES:

 

·         Measured Transmission Spectra for Color Pixels

                                               

·         Measured Film Thickness of TiO2 on Silicon 

·         Measured Reflection Spectra over a MEMS Device Inside/Outside a Via-hole

·         4. Digital Imaging Function in MSP300 System

NOTE:

·         System configuration and Specifications subject to change without notice

·         * Film property, surface quality and layer stack dependent

·         Customized system available for special applications

·         TFProbe is registered trademark of Angstrom Sun Technologies Inc.