企业性质生产商
入驻年限第3年
Lifetime range | 0 - 300 ns |
Lifetime resolution | less than 100 ps (single pixel) |
Speed | 2 lifetime images per second (full frame) |
Spatial resolution | 26 lp/mm (Gen II); 19 lp/mm (Gen III) |
Sensitivity | single photon |
Intrascene dynamic range | 12 bit |
Camera input format | 1 inch |
Effective pixel size | 10.3 μm square (12,9 for lens coupled CCD) |
Signal shape | Sinusoidal |
Frequency range | 1 MHz – 120 MHz |
Frequency adjustment resolution | 1 kHz |
Frequency deviation | 100 ppm max. |
Harmonics suppression | Better than 25 dB |
Output 1 Type a: MultiLED AC signal level DC current adjust | Capable of driving lightsource type a, optionally b and c Adjustable in 250 steps 0 – 1000 mA, 12 bit resolution |
Optional lightsource outputs: Type b: Modulated laser diode AC signal level DC level adjust Type c: AOM for CW laser AC signal level Frequency Output 2 AC signal level AC signal after amplification | 0.00 – 1.00 V peak-peak 0.00 – 1.00 V 0.00 – 1.00 V peak-peak Half the frequency of output 2 To image intensifier Adjustable from –50 to 0 dBm 15 Vpp nom. |
External trigger input | LVTTL (phase shift on falling edge or rising edge) |
Impedance | 50 Ω |
Phase adjustment range | 0 - 360° in 1° steps |
Phase deviation | < 0.01° |
Cathode voltage DC | Adjustable from –150 V to +15 V |
MCP voltage (gain) DC | Adjustable from 450 – 1000 V max. |
Anode voltage DC | Fixed 6 kV |
Peak wavelengths (nm), approximately | 405 (CFP), 445 (cerulean, CFP), 470 (GFP), 535 (TRITC), 630 (CY5), others on request |
Number of mounted LEDs | 3 (standard), or 4 (maximum) |
Modulation frequency | up to at least 80 MHz |
LEDs switching time | 200ms |
Coupling | Compatible with existing Hg and Xe microscope adapters |
Lifetime drift | less than 30 ps* |
Optional Temperature stabilization for long-term (hours) lifetime stability | Active thermoelectric water cooling/heating system |
Control temperature range | 5 – 45º C |
Temperature stability (constant load, constant ambient temp) | ± 0.1º C |
Dimensions (l x w x h) | 346 x 109 x 183 mm |
* Measured using stable fluorescent material with single lifetime component of 3.2 ns |
Wavelengths (nm) | 375 (BFP), 405 (CFP), 445 (cerulean, CFP), 488 (GFP), 515 (YFP, Venus), 647 (CY5), others on request |
Number of laser lines | Standard: up to 3 or up to 6; Extreme: up to 4. All combined into one optical fiber output |
Output power (mW) | 20 mW-300 mW, depending on the wavelength |
Modulation frequency | Up to 120 MHz (standard) |
Input signal | Digital: 0...1 V / 50 Ω |
Control interface | RS232 |
Coupling | KineFLEX system, with a single-mode polarization maintaining fiber and either FC-APC, FC-PC or FC-P8 output connector |
Power stability | Standard: 2%*, Extreme: 0.5%* |
Lifetime drift | Standard: less than 50 ps*, Extreme: less than 20-30 ps* |
Dimensions (l x w x h) | 19" rack housing. MultiLASER-3: 480 x 484 x 88 mm; MultiLASER-4 and 6: 610 x 484 x 132 mm |
Options | • Multi-channel excitation • Two single-mode optical fiber outputs • Custom fiber outputs on special request |
* Measured using stable fluorescent material with single lifetime component of 3.2 ns |