找仪器

Honeywell DC2500-EB-0B00-200-00000-00-0 1/4-DIN Temperature Controller, Universal; Set Pt/Relay/1 SPST

科尔帕默仪器(上海)有限公司

企业性质授权代理商

入驻年限第5年

营业执照已审核
同类产品温度控制器与报警器(62件)
Next generation of industrial universal digital controllers (UDC)
  • IP66- and NEMA 4X-rated faceplate allows the controller to be used in washdown applications
  • Accutune III™ fuzzy logic programming
  • Accuracy of +/- 0.25% full-scale, 16-bit resolution
  • Available in 1/4-DIN size
  • Includes setpoint programing

规格与描述

  • 最高温度 (° F)150
  • ZD温度 (° F)-13
  • ZD温度 (° C)-25
  • 最高温度 (° C)65
  • 准确性 ±0.25% full-scale
  • 分辨率0.1⁰ or 1⁰, selectable
  • 控制输入 - RTDYes
  • 控制输入 - 热电偶Yes
  • 控制输出 1Relay: Contact, SPDT, 3A @ 240 VAC
  • 报警输出Yes
  • 外壳等级NEMA 4X (IP66)
  • 显示类型Dual display for PV and SV (Process value and set value), 4-digit 7-segment
  • 功率 (VAC)90 to 264
  • 描述1/4-DIN Temperature Controller, Universal; Set Pt/Relay/1 SPST

主要特点

  • IP66- and NEMA 4X-rated faceplate allows the controller to be used in washdown applications
  • Accutune III™ fuzzy logic programming
  • Accuracy of +/- 0.25% full-scale, 16-bit resolution
  • Available in 1/4-DIN size
  • Includes setpoint programing

关于该商品的更多信息

These microprocessor-based controllers are the next generation of UDC controllers and offer a high degree of functionality and reliability. Ideal for regulating temperature in a variety of applications including furnaces, ovens, environmental chambers, packaging machinery, plastic processing and more.
Features Diagnostic feature monitors the condition of the thermocouple — to determine whether it's good, failing, or in danger of imminent failure.
Heater breaker alarm continuously checks the output circuit to ensure the heater has not failed.
Accutune III™ software with fuzzy logic overshoot suppression, and true plug-and-play tuning algorithm to tune both the heat and cool side of a duplex control.
Universal power supply covers voltage range of 90 to 264 VAC, 50/60 Hz, which conforms to the standard AC voltages found worldwide.
Set points that can be configured for either two local setpoints or one local and one remote setpoint. (models 89556-40 thru 89556-43)
PV hot start allows the controller to initialize the local setpoint at the current PV value upon power start up in the event of power loss.
Dual set tuning: configured PID parameters can be selected automatically based upon the PV or SP value.
Second input option provides a second linear voltage or current input.
Dual line LED with the capability of displaying multi-language configuration prompts. A 4 character upper display and a 6 character, 14-segment, alphanumeric lower display.
High/Low Limit Controller (model 89556-44) is designed to provide a safety shut-off and optional alarm. A latched relay output is activated when the process parameter either exceeds or falls below the desired value, providing a fail-safe cutoff which has to be manually reset before the process can continue. Features universal input and is FM approved.
Call our Application Specialists for more information on these products or to special order a controller with other options.

    热线电话 在线咨询